{"id":6,"date":"2015-03-31T11:08:59","date_gmt":"2015-03-31T11:08:59","guid":{"rendered":"https:\/\/en.kmtech.dk\/?page_id=6"},"modified":"2015-04-28T08:37:31","modified_gmt":"2015-04-28T08:37:31","slug":"breaker-test","status":"publish","type":"page","link":"https:\/\/en.kmtech.dk\/?page_id=6","title":{"rendered":"Breaker testing"},"content":{"rendered":"<table width=\"930\">\n<tbody>\n<tr>\n<td><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-146\" src=\"http:\/\/kmtech.dk\/wp-content\/uploads\/2015\/03\/test11.png\" alt=\"test1\" width=\"300\" height=\"220\" \/><\/td>\n<td><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-147\" src=\"http:\/\/kmtech.dk\/wp-content\/uploads\/2015\/03\/test2.png\" alt=\"test2\" width=\"300\" height=\"220\" \/><\/td>\n<td><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-148\" src=\"http:\/\/kmtech.dk\/wp-content\/uploads\/2015\/03\/test3.png\" alt=\"test3\" width=\"300\" height=\"220\" \/><\/td>\n<\/tr>\n<tr>\n<td width=\"310\">\n<ul>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Tighten all electrical connections in breaker.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Complete cleaning of breaker.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Lubrication of breaker.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Inspection of mechanical parts on breaker.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Inspection of arcing contacts.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Inspection of main contacts.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Measured micro-ohms on the main contacts.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Inspect the coupling coil, gear motor, auxiliary contacts and signal contacts.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Visually check of current transformers.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Complete primary test of measured transformers, measured wire connections.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Protection Relay functions ( trip times and injection test).<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Test Report on each breaker.<\/span><\/li>\n<\/ul>\n<\/td>\n<td width=\"310\">\n<ul>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Tighten all electrical connections in breaker.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Complete cleaning of breaker.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Lubrication of breaker.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Inspection of mechanical parts on breaker.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Inspection of arcing contacts.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Inspection of main contacts.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Measured micro-ohms on the main contacts.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Inspect the coupling coil, gear motor, auxiliary contacts and signal contacts.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Test Report on each breaker.<\/span><\/li>\n<\/ul>\n<\/td>\n<td width=\"310\">\n<ul>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Complete cleaning of breaker.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Lubrication of breaker.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Inspection of arcing contacts.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Inspection of main contacts.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Measured micro-ohms on the main contacts.<\/span><\/li>\n<li style=\"text-align: left;\"><span style=\"font-size: 8pt;\">Test Report on each breaker.<\/span><\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Tighten all electrical connections in breaker. Complete cleaning of breaker. Lubrication of breaker. Inspection of mechanical parts on breaker. Inspection of arcing contacts. Inspection of main contacts. Measured micro-ohms on the main contacts. Inspect the coupling coil, gear motor, auxiliary contacts and signal contacts. Visually check of current transformers. Complete &#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/en.kmtech.dk\/index.php?rest_route=\/wp\/v2\/pages\/6"}],"collection":[{"href":"https:\/\/en.kmtech.dk\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/en.kmtech.dk\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/en.kmtech.dk\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/en.kmtech.dk\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=6"}],"version-history":[{"count":8,"href":"https:\/\/en.kmtech.dk\/index.php?rest_route=\/wp\/v2\/pages\/6\/revisions"}],"predecessor-version":[{"id":179,"href":"https:\/\/en.kmtech.dk\/index.php?rest_route=\/wp\/v2\/pages\/6\/revisions\/179"}],"wp:attachment":[{"href":"https:\/\/en.kmtech.dk\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=6"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}